3) North and South 2X4 Conclusion Walls: Eventually, I am envisioning using the “breathable house wrap” and “clever vapor retarder like Membrane” similarly Positioned on possibly side with the Rockwool insulation for the attic’s conclusion walls.
I've been believing that following the siding is eliminated it might be doable to pry off the board sheathing and Slash/pull out the poly at Every stud bay. Then re-put in the boards or apply all new sheathing and stick with it with no matter what wall assembly you want. Does this look like a workable procedure to any person? GBA Editor Martin Holladay
That could imply one” polyiso on the attic side on the studs, then mineral wool in the wall (I’m assuming 2x4 partitions listed here, In case you have 2x6s you will need thicker foam to keep up the exact same ratio of batts to foam and also the ratio may be the critical aspect) and you’re very good to go. When you don’t choose to use rigid foam on the attic facet of your partitions, then I’d tack up some breathable housewrap (don’t use poly below!), then batts, and I’d use a smart vapor retarder like MemBrain on the inside beneath the drywall. If this doesn’t sound like what you’re attempting to do, submit a drawing showing where you would like to insulate to assist everyone in this article determine what we need to know in order to help you. Bill
I just skimmed as a result of searching for some sign why the last system of sheathing was taken off, adhesive utilized then re-hooked up but could not obtain it. Undecided what the goal of which was either.
The remainder of your tips ALL seem completely realistic, pretty doable and will type an outstanding "highway map" for the way to continue. Just to test my mettle, I not long ago received an estimate from the reputable insulation business full a whole Johns Manville TempControl Mineral Wool version of my insulation undertaking for $3K.
a perform of your dew issue temperature of the inside air, the amount of air leakage in the wall, along with the vapor permeability of your components within the wall. Little amounts of condensation will not be a dilemma Should the wall is allowed to dry to the outside.
The batten strips marginally compressed the rock wool panels and held the insulation in place as we continued to stack it. Since the insulation went up and fully wrapped the two-story residence, I marveled at how snug the continual rock wool wrap manufactured the structure appear, just like the thick wool comforter That may have held us heat in less complicated times.
You advocate- to setup residence wrap from foundation wall right before installing insulation ? What for ? To Restrict dampness traveling from CMU wall to insulation ?
Chris was aiming to achieve a high-overall performance, low-energy dwelling, still he comprehended that his early reworking selections restricted his options going forward. A person of those restricting choices was the set up of the polyethylene vapor barrier on the inside facial area of his exterior wall framing as he gutted and remodeled Just about every space.
Humidity is more of a major issue Within this weather than in areas that receive twenty inches or much less of rain annually
Should you examine through the different article content on GBA, you read more will get an idea of lots of the essential concepts that can help you to be aware of where issues should really Choose most effective functionality. It is possible to generally talk to in Q+A way too if you get stumped of if you have a circumstance that does not very fit any with the examples from the content articles.
I concur with all of that Monthly bill said and hope that you're not overthinking this. In attics like yours there is a simple and affordable solution: Pull out the aged insulation, set a lot of work into air sealing the ceiling from your attic, and blow in as much insulation as it is possible to find the money for, with blocking and vent baffles within the eaves to circumvent wind washing and maintain air move to the ridge vent. This is messy and someday awkward to try and do, and also incredibly Do-it-yourself-pleasant function.
>"To limit dampness traveling from CMU wall to insulation ? Isn’t we are attempting to Permit the wall assembly to dry to the interior?" Concrete & CMU foundations need not dry toward the interior. These varieties of foundations operate just wonderful even if fully saturated with water, and therefore are not degraded by moisure Unless of course It can be constantly shifting throughout the concrete at a higher price taking minerals with it.
Thank you in your replies . I have read through peaceful a little bit on a matter and In most cases concur with rigid insulation notion.